High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable

Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: High Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire

Contact Supplier

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YJV
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
YJV
Brand
Jinshui
Transport Package
Wooden Drun
Specification
YJV
Trademark
JINSHUI
Origin
China
HS Code
8544492100
Production Capacity
5000km/Week

Product Description

Cu/XLPE/SWA/PVC Power Cable YJV22

High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable


Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.


Executive Standard: 


It is manufacture under GB/T12706-2002 standard(The same as IEC60502). 

Application: 

It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. 
It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and 
communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC
 insulated power cable. 

Using features: 

1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV. 

2. No. of core: Single-core, Three-core. 

3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250. 

4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997. 

5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated. 

6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter. 

7. Working Frequency Voltage Test:. 

For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
 
This series includes:
 
Copper (aluminum) core, XLPE insulated and sheathed power cables. 

Copper (aluminum) core, XLPE insulated, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables. 

Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables 





High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable
High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable
High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable
High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable
High Quality Medium Voltage XLPE Insulated Unarmoured Power Cable

Send your message to this supplier

*From:
*To:
avatar Mr. Jin Shiqiang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
533
Year of Establishment
2007-04-30