Application: | Overhead Power Distribution |
---|---|
Conductor Material: | Aluminum |
Insulation Material: | XLPE |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Service drop ABC cable Triplex 1/0awg Neritina ICEA S-76-474
1.Application
ABC cable is primarily used on lighting, outdoor lighting, and temporary service for construction.To be used at voltages of 600V phase-to-phase or less,and the conductor temperatures no exceeds 75 degrees for polyethylene(PE)
insulated conductors or 90 degrees for corsslinked polyethylene(XLPE) insulated conductors.
2.ABC cable meets of exceeds the following specifications
2.1. Aluminum cable,1350-H19 for electrical purposes.
2.2.Aluminum conductors,concentric lay stranded.
2.3.Aluminum conductor,concentric lay stranded,coated steel reinforced(ACSR).
2.4.Concentric lay stranded,6201-T81 conductors.
2.5.Compressed round stranded aluminum conductors using single input conductor.
3.ABC cable based on ASTM ANSI/ICEA S-76-474
Phase core: AAC,XLPE cover.
Neutral core: AAC/ACSR/AAAC.
Sizes: 8AWG,6AWG,4AWG,2AWG,1/0AWG,2/0AWG,3/0AWG,4/0AWG,etc.
Specification:Duplex service drop,Triplex service drop,Quadruplex service drop.
4.ABC cable based on IEC standard
4.1.No.cores:1+1,2+1,3+1.
4.2.Nominal sizes of each core
Phase core:10mm2,16mm2,25mm2,35mm2,50mm2,70mm2,95mm2
Neutral core:10mm2,16mm2,25mm2,35mm2,50mm2,70mm2.
4.3.Material of core conductor
Phase core: AAC(all aluminum conductors)
Neutral core: AAAC(all aluminum alloy conductors).
4.4.Material of insulation:XLPE/PE.
5. ABC cable based on NFC33-209 standard
Description | Insulated phase conductors | Average Insulation Thickness |
|||||
Type | Nominal Cross-section area |
wire No. in the conductor |
Max. resistance at 20°C |
Average dia. of conductors |
Rated strength |
||
mm2 | No. | Ohm/km | Mini. mm |
Max. mm |
Mini kN |
mm | |
Phase,Neutral, and Public Lighting |
16 | 7 | 1.91 | 4.6 | 5.1 | 1.9 | 1.2 |
25 | 7 | 1.2 | 5.8 | 6.3 | 3 | 1.4 | |
35 | 7 | 0.868 | 6.8 | 7.3 | - | 1.6 | |
50 | 7 | 0.641 | 7.9 | 8.4 | - | 1.6 | |
70 | 12 | 0.443 | 9.7 | 10.2 | - | 1.8 | |
95 | 19 | 0.32 | 11 | 12 | - | 1.8 | |
120 | 19 | 0.253 | 12 | 13.1 | - | 1.8 | |
150 | 19 | 0.206 | 13.9 | 15 | - | 1.7 | |
Porter | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 16.6 | 1.6 |
70 | 7 | 0.5 | 10 | 10.2 | 20.5 | 1.5 | |
95 | 19 | 0.343 | 12.2 | 12.9 | 27.5 | 1.6 |
Large scale,Strong capacity;
Reliable quality&Best prices!
Welcome to enquiry at any time!