• Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina
  • Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina
  • Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina
  • Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina
  • Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina
  • Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina

Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina

Application: Overhead
Conductor Material: Aluminum
Insulation Material: XLPE
Jacket: Bare
Rated Voltage: 0.6/1kv
Transport Package: Wooden Drum or as Your Requirement
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Henan, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 18 foreign trading staff(s) and 16 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (24)

Basic Info.

Model NO.
ABC Cable
Trademark
jINSHUI
Origin
Henan, China (Mainland)

Product Description

Product Description

Specifications
 
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger, A cable factory in China,Since 1984 
400 staff,12,000 m2 


 
pplications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.

Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474. 

Note : 
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition
 
Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina Overhead ABC Cable/Aluminum XLPE Cable ACSR 3*1/0AWG Neritina

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
533
Year of Establishment
2007-04-30